Oil Check 500 - The monitoring system for permanent highly precise measurement of the vaporous residual oil content compressed air, nitrogen and gases
"Forced Pressure Variation" for long-term stable measurement results - Auto-calibration
Thanks to the innovative "Forced Pressure Variation" measuring method, the Oil Check 500 generates reference gas internally in different mass concentrations. With the help of this process, which is intellectually protected by CS INSTRUMENTS, components in the measurement signal caused by ageing or contamination, in particular long-term drifts, can be compensated. No wearing parts such as activated carbon filters are necessary for the generation of zero air. The result is a low-maintenance and long-term stable measurement
Specifications
Measured Medium |
N/A
Compressed air, nitrogen, (free from aggressive, corrosive, acid, toxic, flammable and oxidizing components). Further gases on request |
Measuring Unit |
N/A Residual oil content in mg oil/norm m³ referred to 14.5 psi [abs], +68 F, 0% relative humidity, in accordance with ISO 8573-1 |
Identifiable Substances |
N/A Aromatic Hydrocarbons Functional Hydrocarbons Hydrocarbons |
Ambient Temperature |
N/A +68 to +113 ºF |
Relative Humidity without Condensation |
N/A ≤ 75 % |
Compressed Air Temperature |
N/A +68 to +113 ºF |
Operational Overpressure1 | N/A 43.5 to 130.5 psi |
Humidity of Measured Gas |
N/A ≤ 40% relative humidity, pressure dew point maximum +50 ºF, non-condensable humidity |
Compressed Air Connection |
N/A G-1/4 in. Female Thread According to International Organization for Standardization (ISO) 228-1 |
Measured Values |
N/A mg/norm m³, pressure and temperature compensated residual oil vapor content |
Measuring Range2 | N/A 0.001 to 5 mg/m³ |
Detection limit (Residual Oil) |
N/A 0.001 mg/m³ |
Approximate Flow of Measuring Gas |
N/A 0.042 ft³/min |
Note for Approximate Flow of Measuring Gas |
N/A Referred to to 14.5 psi [abs] and +68 F, (atmospheric conditions) |
Alternating Current (AC) Voltage |
N/A 100 to 240 V |
Phase |
N/A 1 |
Grounding |
N/A Protective Earth (PE) |
Frequency |
N/A 50 to 60 Hz |
Voltage Tolerance |
N/A ±10 % |
Digital Output |
N/A Ethernet Via DS 400/500 RS 485 Interface (Modbus-Remote Terminal Unit (RTU)) |
Analog Output Current (Electrically Isolated) |
N/A 4 to 20 mA |
Optional Output |
N/A 2 x 4...20 mA analog output (electrically isolated), 2 alarm relays for external alarm unit, alarm values freely adjustable |
Operating Hours Counter |
N/A Integrated |
Field of Application
Field of Application |
N/A After activated carbon filter, after activated carbon adsorber, after oil-free compressor, always with connected upstream filtration and dryer |
Portable Solution
Portable Solution |
N/A
Item # - Z699 0174 Description - Portable sampling system consisting of 6.56 ft PTFE hose, quick coupling (oil- and grease-free) Item # - 0500 5012 Description - DS 500 mobile - intelligent chart recorder with 4 sensor inputs Item # - 0554 8040 Description - CS Basic - data evaluation in graphic and table form - readout of the measured data via USB or Ethernet. License for 2 working places |
Features
Features |
N/A
|
Additional Information
N/A
Oil Check 500 portable- Residual oil measurement of the vaporous oil content from 0.001...5 mg/m³, 43.5 ... 130.5 psi. High-precision PID sensor, innovative “Forced Pressure Variation“ measuring method, with integrated display, with 4...20 mA analog output and digital Modbus RTU interface, incl. calibration certificate, in a robust flight case. Connection cable ODU/ODU 16 ft |
- 1 Optional pressure reducer connected upstream for up to 4350 psi
- 2 Higher Measuring Ranges On Request