Medical Lubricated Vane Open Vacuum Systems
Medical, Laboratory and Industrial Vacuum Pump Systems
Medical Lubricated Vane Open Systems
The lubrication from the oil in this pump results in higher efficiencies, lower operating temperatures and lower sound levels than oil-less designs. The lubricated vane design also results in the highest ultimate vacuum levels of all the technologies.
The lubrication from the oil in this pump results in higher efficiencies, lower operating temperatures and lower sound levels than oil-less designs. The lubricated vane design also results in the highest ultimate vacuum levels of all the technologies.
Unit of Measure
Items |
![]() VVTD0153 1.5 HP Duplex Tankmount Medical Lubricated Vane Open System VVTD0153 |
![]() VVTD0203 2 HP Duplex Tankmount Medical Lubricated Vane Open System VVTD0203 |
![]() VVTD0303 3 HP Duplex Tankmount Medical Lubricated Vane Open System VVTD0303 |
![]() VVTD0403 5 HP Duplex Tankmount Medical Lubricated Vane Open System VVTD0403 |
![]() VVTD0503 5 HP Duplex Tankmount Medical Lubricated Vane Open System VVTD0503 |
|||||
Description | N/A The lubrication from the oil in this pump results in higher efficiencies, lower operating temperatures and lower sound levels than oil-less designs. The lubricated vane design also results in the highest ultimate vacuum levels of all the technologies. | |||||||||
Length (A) | N/A 54 in | N/A 54 in | N/A 54 in | N/A 54 in | N/A 58 in | |||||
Width (B) | N/A 34 in | |||||||||
Height (C) | N/A 85 in | N/A 85 in | N/A 85 in | N/A 85 in | N/A 87 in | |||||
Inlet Connection Size | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | N/A 2 in | |||||
Outlet Connection Size | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | N/A 2 in | |||||
Pump Power | N/A 1.5 hp | N/A 2 hp | N/A 3 hp | N/A 5 hp | N/A 5 hp | |||||
Air Flow at 19 inHg1 | N/A 7 scfm | N/A 11 scfm | N/A 17 scfm | N/A 25 scfm | N/A 37 scfm | |||||
Tank Capacity | N/A 80 gal | |||||||||
Tank Orientation | N/A Vertical | |||||||||
Compressor Capacity | N/A 3,251 Btu/hr | N/A 4,335 Btu/hr | N/A 6,503 Btu/hr | N/A 10,838 Btu/hr | N/A 10,838 Btu/hr | |||||
Sound Level | N/A 63 dBA | N/A 66 dBA | N/A 66 dBA | N/A 68 dBA | N/A 74 dBA | |||||
System Full Load Current (F.L.A) at 208 Volts | N/A 11 A | N/A 13.2 A | N/A 18.8 A | N/A 29.6 A | N/A 30.6 A | |||||
System Full Load Current (F.L.A) at 230 Volts | N/A 10.8 A | N/A 12.8 A | N/A 17.6 A | N/A 28 A | N/A 27.8 A | |||||
System Full Load Current (F.L.A) at 460 Volts | N/A 6.4 A | N/A 7.4 A | N/A 9.8 A | N/A 15 A | N/A 14.9 A | |||||
System Weight | N/A 1,200 lb | N/A 1,300 lb | N/A 1,400 lb | N/A 1,500 lb | N/A 1,400 lb | |||||
Brands | N/A Powerex® | |||||||||
Electrical Panel Opening | N/A 42 in | |||||||||
Minimum Clearance for Ease of Maintenance | N/A 24 in | |||||||||
Motor Voltage | N/A 208 V230 V460 V | |||||||||
Phase | N/A 3 | |||||||||
Power Supply Frequency | N/A 60 Hz | |||||||||
Vacuum System |
N/A
The Powerex enclosed medical vacuum system is designed to create a suction to remove unwanted fluids or gases from hospital working areas. The enclosed medical vacuum system package is compliant with the NFPA 99 requirements for Risk Category 1 systems. Each system is completely tested before shipment and includes: • Multiple vacuum pumps and associated equipment • ASME air receiver (optional) • Medical control panel Each pump is factory piped to a common intake manifold. Intake isolation valves are included. Vibration isolation pads are included with the system. |
|||||||||
Rotary Vane Vacuum Pump |
N/A
The medical vacuum pumps shall be of the rotary vane air-cooled design. Each vacuum pump shall be direct-driven through a shaft coupling by a TEFC electric motor. Belt drives shall not be permitted. The vacuum pumps shall be mounted on vibration isolators. • Each vacuum pump shall be air-cooled and have absolutely no water requirements. • Each pump is equipped with a 10 micron inlet filter for removal of particulates. • Lubrication shall be provided by an integral, fully recirculating oil supply that is filtered by an automotive-type, spin-on oil filter. Non-recirculating (once-through) or partial re-circulating oil supply systems shall not be permitted. Each vacuum pump shall be capable of operation with ISO 100 viscosity oil. • The oil separation systems shall be integral and shall consist of no less than three stages of internally installed oil and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, oil mist elimination, and smoke elimination, and shall be capable of removing 99.9+ percent of all oil and smoke particles from the exhaust gas stream. • Each vacuum pump shall include a built-in, antisuck-back valve, mounted at the pump inlet, and three sliding vanes |
|||||||||
Motor | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. | |||||||||
Receiver | N/A The internally lined ASME rated vacuum receiver shall be equipped with a sight gauge, isolation valves, and a manual drain. | |||||||||
Control Panel |
N/A
The control system provides automatic lead/lag sequencing and automatic alternation of all pumps in order to equalize the amount of usage among the available vacuum pumps. The Premium NFPA Control panel shall include a gateway server card and all features listed below:
|
|||||||||
Available Options |
N/A
|
|||||||||
Note | N/A 3 Year Limited Warranty | |||||||||
Additional Information |
N/A
Benefit & Features
|
|||||||||
|