Medical Claw Open Vacuum Systems
Medical, Laboratory and Industrial Vacuum Pump Systems
Medical Claw Open Systems
The claw pump design is extremely efficient and has very low maintenance cost; because there is no actual contact between the rotors and the cylinder wall, parts that need replacing or required maintenance is minimized.
The claw pump design is extremely efficient and has very low maintenance cost; because there is no actual contact between the rotors and the cylinder wall, parts that need replacing or required maintenance is minimized.
Unit of Measure
Items |
![]() CVTD0203 2 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0203 |
![]() CVTD0203V 2 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0203V |
![]() CVTD0303 3 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0303 |
![]() CVTD0303V 3 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0303V |
![]() CVTD0504A 4 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0504A |
|||||
Description |
N/A
Medical Claw Open Systems The claw pump design is extremely efficient and has very low maintenance cost; because there is no actual contact between the rotors and the cylinder wall, parts that need replacing or required maintenance is minimized. |
|||||||||
Length (A) | N/A 71 in | N/A 71 in | N/A 71 in | N/A 71 in | N/A 77 in | |||||
Width (B) | N/A 42 in | N/A 42 in | N/A 42 in | N/A 42 in | N/A 43 in | |||||
Height (C) | N/A 68 in | N/A 68 in | N/A 68 in | N/A 68 in | N/A 72 in | |||||
Inlet Connection Size | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | N/A 1.5 in | N/A 2 in | |||||
Outlet Connection Size | N/A 1 in | |||||||||
Pump Power | N/A 2 hp | N/A 2 hp | N/A 3 hp | N/A 3 hp | N/A 4 hp | |||||
Air Flow at 19 inHg1 | N/A 16 scfm | N/A 16 scfm | N/A 21 scfm | N/A 21 scfm | N/A 29 scfm | |||||
Tank Capacity | N/A 80 gal | N/A 80 gal | N/A 80 gal | N/A 80 gal | N/A 120 gal | |||||
Tank Orientation | N/A Horizontal | N/A Vertical | N/A Horizontal | N/A Vertical | N/A Horizontal | |||||
Compressor Capacity | N/A 4,335 Btu/hr | N/A 4,335 Btu/hr | N/A 6,503 Btu/hr | N/A 6,503 Btu/hr | N/A 8,670 Btu/hr | |||||
Sound Level | N/A 70 dBA | N/A 70 dBA | N/A 70 dBA | N/A 70 dBA | N/A 79 dBA | |||||
System Full Load Current (F.L.A) at 208 Volts | N/A 14.4 A | N/A 14.4 A | N/A 20.8 A | N/A 20.8 A | N/A 22 A | |||||
System Full Load Current (F.L.A) at 230 Volts | N/A 13.2 A | N/A 13.2 A | N/A 18.8 A | N/A 18.8 A | N/A 20.4 A | |||||
System Full Load Current (F.L.A) at 460 Volts | N/A 7.6 A | N/A 7.6 A | N/A 10.4 A | N/A 10.4 A | N/A 11.2 A | |||||
System Weight | N/A 1000 lb | N/A 1000 lb | N/A 1,200 lb | N/A 1,200 lb | N/A 1,400 lb | |||||
Brands | N/A Powerex® | |||||||||
Electrical Panel Opening | N/A 42 in | |||||||||
Minimum Clearance for Ease of Maintenance | N/A 24 in | |||||||||
Motor Voltage | N/A 208 V230 V460 V | |||||||||
Phase | N/A 3 | |||||||||
Power Supply Frequency | N/A 60 Hz | |||||||||
Vacuum System |
N/A
The Powerex medical vacuum system is designed to create a suction system to remove unwanted fluids or gases from hospital/ laboratory working areas. The medical vacuum system package is compliant with the NFPA 99 requirements for Risk Category 1 systems. Each system is completely tested before shipment and includes: • Multiple vacuum pumps and associated equipment. • AMSE air receiver. • Medical control panel. Each pump is factory piped to a common intake manifold. Vibration isolation pads are included with the system. |
|||||||||
Rotary Vane Vacuum Pump |
N/A
Each pump shall be a rotary claw type vacuum pump, and shall be direct-driven through a shaft coupling by a C-face, TEFC electric motor. • Each vacuum pump shall be dry-running, featuring two claw-type, non-contacting rotors and shall not require any sealing fluid in the pumping chamber, assuring virtually maintenance-free operation. • Each vacuum pump shall include an internal relief valve, and a built-in, anti-suck-back valve mounted at the pump inlet. • Each pump within the system shall include a check valve, inlet and discharge flex connectors, a 5 micron inlet filter and a pump isolation valve. |
|||||||||
Motor | N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation. | |||||||||
Receiver | N/A The system shall include an ASME rated air receiver. The tank shall be equipped with a vacuum gauge, a sight gauge, by-pass valves, and a manual drain. | |||||||||
Control Panel |
N/A
The control system provides automatic lead/lag sequencing and automatic alternation of all pumps in order to equalize the amount of usage among the available vacuum pumps. The Premium NFPA Control panel shall include a gateway server card and all features listed below:
|
|||||||||
Available Options |
N/A
• Oxygen assured pumps - prepared for use in WAGD systems. • Internal tank lining for corrosion resistance. • Variable Frequency Drive (VFD) Control Panel – with Premium NFPA controls. |
|||||||||
Note | N/A 3 Year Limited Warranty | |||||||||
Additional Information |
N/A
Benefit & Features
|
|||||||||
|